{"title":"Surge Protection Device","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eEvery day, your valuable electronic equipment is at risk from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epower surges and transient overvoltages\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Whether caused by a distant lightning strike, grid switching, or large motors starting up, these voltage spikes can silently degrade or instantly destroy sensitive electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e Surge Protection Device (SPD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is your first line of defense. Installed in your main distribution board, it continuously monitors the incoming power supply and safely diverts excess voltage to ground before it can reach your equipment. Available in various configurations for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esingle-phase and three-phase systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this SPD provides reliable, maintenance-free protection for your home, office, or industrial facility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWith \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh surge current handling capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethermal disconnection protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eclear visual status indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, you can trust that your equipment is safe—even when you're not there.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"surge-protection-device-spd-ac-power-line-surge-arrester-shield-home-industrial-equipment-from-lightning-power-surges-type-2-protection","title":"Surge Protection Device (SPD) | AC Power Line Surge Arrester | Shield Home \u0026 Industrial Equipment from Lightning \u0026 Power Surges | Type 2 Protection","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e⚡ Protect Your Valuable Equipment from Deadly Power Surges\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComprehensive Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Shields against lightning strikes, switching surges, and grid fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMulti-Application:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Perfect for homes, offices, industrial facilities, and solar systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Surge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dissipates massive transient energy safely to ground.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in standard distribution boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVisual Status Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Know at a glance if protection is active.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003ctable style=\"width: 99.9987%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 47.8252%;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 52.0682%;\"\u003e\u003cspan\u003eType 2 Model\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003eSPD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003eType 2 (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMax Continuous Voltage (Uc)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003e275V \/ 440V (select)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eNominal Discharge Current (In)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003e20kA (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMax Discharge Current (Imax)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003e40kA (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eImpulse Current (Iimp)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003eN\/A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage Protection Level (Up)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003e≤ 1.5kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003e\u0026lt; 25 ns\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003e2P,\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003e35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003eUp to 35mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eStatus Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003eVisual (Green\/Red)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eRemote Signaling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003e-40°C to +80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCertification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.8252%;\"\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.0682%;\"\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_424b356d-c631-48e7-9539-5d63866b9c0e.jpg?v=1772347234\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_372afcdd-2df3-4d57-aa60-85246cc717ca.jpg?v=1772347233\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_a12f3301-6b0f-4fa9-80b6-c91a06afa7aa.jpg?v=1772347234\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_6bd4b5f0-7658-4e3e-abd5-9e2140c7c38e.jpg?v=1772347234\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_3a2c23fd-f9cf-429f-9f6e-baa4f4336ce4.jpg?v=1772347234\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_82682938-b66f-43f2-9b15-1f3de3339c0b.jpg?v=1772347234\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_bc99f544-588f-4af1-bfde-80044685f8dc.jpg?v=1772347234\" alt=\"\"\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"2P AC275V \/ 20KA","offer_id":54039090266484,"sku":null,"price":2.0,"currency_code":"USD","in_stock":true},{"title":"2P AC275V \/ 40KA","offer_id":54039090299252,"sku":null,"price":3.0,"currency_code":"USD","in_stock":true},{"title":"2P AC275V \/ 60KA","offer_id":54039090332020,"sku":null,"price":3.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_3e8f7d31-795c-4519-8176-f9c16e45024e.png?v=1772347355"},{"product_id":"4p-ac-spd-surge-protection-device-lightning-surge-arrester-for-3-phase-power-lines-type-1-2-industrial-grade-protection-iec-61643-11-compliant","title":"4P AC SPD Surge Protection Device | Lightning \u0026 Surge Arrester for 3-Phase Power Lines | Type 1\/2 Industrial-Grade Protection | IEC 61643-11 Compliant","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e🏭 Industrial-Strength Surge Protection for Three-Phase Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4-Pole Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects L1, L2, L3, and Neutral – complete coverage for 3-phase installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Surge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Handles massive transient energy from lightning strikes and grid switching.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType 1 \u0026amp; Type 2 Options:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Choose the protection level that matches your risk.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in industrial control panels and distribution boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVisual Status Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e At-a-glance confirmation of protection status.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003ctable style=\"width: 99.9987%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 47.1544%;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 52.7391%;\"\u003e\u003cspan\u003eType 2 Model\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eSPD-4P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eType 2 (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003e4P (L1, L2, L3, N)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMax Continuous Voltage (Uc)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003e275V \/ 385V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eNominal Discharge Current (In)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003e20kA (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMax Discharge Current (Imax)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003e40kA (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eImpulse Current (Iimp)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eN\/A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage Protection Level (Up)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003e≤ 1.5kV (L-N)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003e\u0026lt; 25 ns\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003e35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eUp to 35mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eStatus Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eVisual (Green\/Red)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eRemote Signaling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003e-40°C to +80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCertification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.1544%;\"\u003e\u003cstrong\u003e\u003cspan\u003eEnd of Life Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.7391%;\"\u003e\u003cspan\u003eThermal disconnection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_31129a3b-6d1e-4417-8ce3-e3acbadc3fc3.jpg?v=1772347808\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_b2a9daf8-e73f-4412-a0b6-99a389d3797f.jpg?v=1772347807\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_66b42378-555b-4f65-9d35-8e33235b0415.jpg?v=1772347807\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_508bfbc1-1355-4efc-b7fd-91af9ba04274.jpg?v=1772347808\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_9d99c4e2-74b1-4582-8a00-34ca6c55751e.jpg?v=1772347808\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_b05aa20b-8155-4940-9fe7-bd7fe5ee20c8.jpg?v=1772347807\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_38eb1986-9cf6-4f79-b0ef-416f388d7b65.jpg?v=1772347807\" alt=\"\"\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"4P red 275V \/ 20KA","offer_id":54039092756852,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"4P red 275V \/ 40KA","offer_id":54039092789620,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"4P red 385V \/ 20KA","offer_id":54039092822388,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"4P red 385V \/ 40KA","offer_id":54039092855156,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"4P white 275V \/ 20KA","offer_id":54039092887924,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"4P white 275V \/ 40KA","offer_id":54039092920692,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"4P white 385V \/ 20KA","offer_id":54039092953460,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"4P white 385V \/ 40KA","offer_id":54039092986228,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_25d0a4c2-7868-4cc6-96d2-fd5d19634c55.png?v=1772347873"},{"product_id":"dc2p-series-pv-surge-protector-spd-500v-1000v-high-voltage-dc-protection-for-solar-arrays-lightning-surge-arrester-for-photovoltaic-systems-din-rail-mount","title":"DC2P Series PV Surge Protector (SPD) | 500V-1000V High Voltage DC Protection for Solar Arrays | Lightning \u0026 Surge Arrester for Photovoltaic Systems | DIN Rail Mount","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e☀️ Specialized DC Surge Protection for Your Solar Investment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Voltage DC Rated:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available in 1000V models for all common PV array voltages.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2-Pole Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects both positive (+) and negative (-) DC conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType 2 Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ideal for combiner boxes, inverter DC inputs, and array junction boxes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in standard PV distribution boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVisual Status Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e At-a-glance confirmation of protection status.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 50.4268%;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 49.1826%;\"\u003e\u003cspan\u003eDC2P-1000V\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003eSPD-DC2P-1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003eType 2 (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMax Continuous Voltage (Ucpv)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e1000V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eNominal Discharge Current (In)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e20kA (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMax Discharge Current (Imax)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e40kA (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage Protection Level (Up)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e≤ 3.0kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e\u0026lt; 25 ns\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e2P (+ \/ -)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003eUp to 16mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eStatus Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003eVisual (Green\/Red)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eRemote Signaling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eShort-Circuit Withstand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e-40°C to +80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCertification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDimensions (per pole)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1826%;\"\u003e\u003cspan\u003e18mm (1 module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_d098797e-726d-40e7-9745-afb65146b4ab.jpg?v=1772414628\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_d35af31a-f563-4f52-84cf-074701f52e21.jpg?v=1772414628\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_f70a8ff4-07f8-4cee-89c8-85c51cd82a94.jpg?v=1772414628\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_9a0e240f-61ce-4845-a461-7b16690fccbd.jpg?v=1772414629\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_863f627e-0a27-4b38-9b9e-315193c4f091.jpg?v=1772414628\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_b1e283b4-6448-4848-9baa-3d9f2bcd27ca.jpg?v=1772414628\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_32586c2e-af2f-44a0-9800-26dfc9dff9d6.jpg?v=1772414628\" alt=\"\"\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"20A \/ 2P Orange","offer_id":54040435851636,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"20A \/ 2P Red","offer_id":54040435884404,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"40A \/ 2P Orange","offer_id":54040435917172,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"40A \/ 2P Red","offer_id":54040435949940,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"60A \/ 2P Orange","offer_id":54040435982708,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"60A \/ 2P Red","offer_id":54040436015476,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_bc5fb5d0-e7aa-4c86-869e-d21e7d70bf16.png?v=1772414704"},{"product_id":"dc-surge-protective-device-spd-type-1-2-hkb-hku-pv40-3p-40ka-dc1000v-lightning-arrester-for-pv-systems-red-replace-indicator-ce-certified","title":"DC Surge Protective Device (SPD) Type 1+2 HKB\/HKU-PV40 | 3P 40kA DC1000V Lightning Arrester for PV Systems | Red=Replace Indicator, CE Certified","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e☀️ Ultimate DC Surge Protection for High-Voltage Solar Arrays – Type 1+2 Combined\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHybrid A\/B Type (Type 1+2):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects against both direct lightning strikes (10\/350µs) and switching surges (8\/20µs).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1000V DC Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for commercial and utility-scale PV systems up to 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3-Pole Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects positive (+), negative (-), and ground – complete isolation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e40kA Surge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e High-energy dissipation for the most demanding installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRed=Replace Visual Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e At-a-glance status monitoring – green = good, red = replace.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCE Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Meets European safety standards for photovoltaic applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHKB\/HKU-PV40 3P\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHKB-PV40 \/ HKU-PV40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eType 1+2 (Class I+II \/ A+B)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC side of photovoltaic systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3P (+, -, PE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMax Continuous Voltage (Ucpv)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNominal Discharge Current (In)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20kA (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMax Discharge Current (Imax)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40kA (8\/20µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eImpulse Current (Iimp)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e12.5kA (10\/350µs) per pole\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage Protection Level (Up)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 3.5kV (+, - to PE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 25 ns\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eShort-Circuit Withstand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemporary Overvoltage (TOV)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1200V DC, 5 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-35mm² (stranded\/solid)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStatus Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisual (Green\/Red window)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRemote Signaling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional (volt-free contact)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL94 V-0 flame-retardant PC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (finger-safe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDimensions (W x H x D)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e54mm x 90mm x 68mm (3 modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCertification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_dac99ace-0d10-40b2-958d-bdacd9b41e57.jpg?v=1772414932\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_97a4d670-1439-45a4-893c-99f8aa4bdef9.jpg?v=1772414932\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_bde640ea-0553-475a-bb92-82701a7ab23c.jpg?v=1772414933\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_a6e329f2-c3bd-4b80-8ba8-12e515887225.jpg?v=1772414933\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_346c5131-61ef-40e3-9a4d-5e825ba83845.jpg?v=1772414932\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_53ab69d6-ccf7-4dfc-a278-a3513f0bec8a.jpg?v=1772414932\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_e6255197-c5d9-4d1e-8d3f-06ef474d6f35.jpg?v=1772414932\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/08_3a8ae637-bc17-43fe-b60b-948c9433bd9a.jpg?v=1772414932\" alt=\"\"\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"A type \/ 20KA","offer_id":54040437096820,"sku":null,"price":9.0,"currency_code":"USD","in_stock":true},{"title":"A type \/ 40KA","offer_id":54040437129588,"sku":null,"price":9.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 20KA","offer_id":54040437162356,"sku":null,"price":9.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 40KA","offer_id":54040437195124,"sku":null,"price":9.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_856a29c0-e182-4d71-be4d-9d9f8dfdf986.png?v=1772414981"},{"product_id":"2p-dc-type-2-surge-protector-spd-high-level-lightning-transient-protection-for-solar-dc-power-systems","title":"2P DC Type 2 Surge Protector (SPD) | High-Level Lightning \u0026 Transient Protection for Solar \u0026 DC Power Systems","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e⚡ High-Performance DC Surge Protection for Solar Arrays \u0026amp; Battery Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType 2 Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e High-level protection against indirect lightning strikes and switching transients.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2-Pole Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Safeguards both positive (+) and negative (-) DC conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Voltage Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available in 500V, 600V, 800V, and 1000V DC models for various system voltages.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Surge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to 40kA discharge capacity – handles major surge events.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVisual Status Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Green means protected – at-a-glance peace of mind.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in combiner boxes, inverter enclosures, and DC panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSolar PV systems and DC power installations represent significant investments – and they're constantly exposed to one of nature's most destructive forces: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elightning and power surges\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Whether from a nearby lightning strike, grid switching transients, or internal system operations, these voltage spikes can destroy expensive equipment in milliseconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2P DC Type 2 Surge Protector (SPD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-level protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e specifically engineered for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esolar arrays, battery storage systems, and DC power distribution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Available in voltage ratings from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e500V to 1000V DC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this surge arrester provides comprehensive protection for residential, commercial, and industrial DC applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWith \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eType 2 classification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (8\/20µs waveform), it's designed to handle indirect lightning strikes and switching surges – the most common threats to DC systems. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-pole (2P) design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e protects both positive and negative conductors, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003evisual status indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e lets you confirm protection status at a glance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDon't let a surge destroy your solar investment. Protect your panels, inverters, and batteries with professional-grade DC surge protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSolar PV Arrays\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect panels and wiring from lightning-induced surges\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCombiner Boxes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCentralized protection for multiple strings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInverter DC Input\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafeguard inverters from incoming DC surges\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBattery Storage Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect batteries and BMS from transients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Distribution Panels\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCentralized protection for DC loads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEV Charging Stations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC fast charging infrastructure protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTelecom DC Power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect -48V DC telecom equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIndustrial DC Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V-1000V DC motor drives and controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_a7911213-09ed-41c0-b87e-c5d6cd0ed137.jpg?v=1773034902\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_674a16d2-4be8-47c4-9c18-f1d30ced7a46.jpg?v=1773034902\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_de0fbd41-9ecc-4171-a87e-3697c1772103.jpg?v=1773034902\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_21c019ab-12d2-4501-a428-e2fed3153515.jpg?v=1773034902\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_d2f6446f-04b8-4623-a317-cf3abe0c01a2.jpg?v=1773034902\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_20ef2bbe-38ec-454d-a33a-814242866a2a.jpg?v=1773034902\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_38e942b6-3abe-4c76-acce-b94d44bbb810.jpg?v=1773034902\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/08_ce2884ae-b90b-402f-b6b6-57a1caa0e2c4.jpg?v=1773034902\" alt=\"\"\u003e\u003c\/p\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"A type \/ 20KA","offer_id":54063006843252,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"A type \/ 40KA","offer_id":54063006876020,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 20KA","offer_id":54063006908788,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 40KA","offer_id":54063006941556,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_a6e397bb-7829-4867-bada-c2a1372c4ea7.png?v=1773034949"},{"product_id":"dc-surge-protective-device-spd-a-b-type-hkb-hku-pv40-3p-40ka-dc1000v-lightning-arrester-red-replace-indicator-ce-certified","title":"DC Surge Protective Device (SPD) A\/B Type HKB\/HKU-PV40 3P 40kA DC1000V Lightning Arrester - Red=Replace Indicator, CE Certified","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e☀️ Ultimate DC Surge Protection for High-Voltage Solar Arrays – Type 1+2 Hybrid\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHybrid A\/B Type (Type 1+2):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects against both direct lightning strikes (10\/350µs) and switching surges (8\/20µs) in one device.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1000V DC Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for commercial and utility-scale PV systems up to 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3-Pole (3P) Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects positive (+), negative (-), and ground (PE) – complete isolation for ungrounded arrays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e40kA Surge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e High-energy dissipation for the most demanding installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRed=Replace Visual Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Green means protected, red means replace – at-a-glance status monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCE Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Meets IEC 61643-31 European safety standards for photovoltaic applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in combiner boxes, inverter enclosures, and DC panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLarge-scale solar installations face an elevated risk from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edirect lightning strikes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esevere surge events\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Standard Type 2 SPDs provide adequate protection for indirect surges, but when your PV array is exposed to direct strikes – common in open fields, rooftops, and high-lightning areas – you need \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eType 1+2 hybrid protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHEVGKEOU HKB\/HKU-PV40 Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eType 1+2 (A\/B Type) DC Surge Protective Device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e engineered for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-voltage photovoltaic systems up to 1000V DC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. With a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-pole (3P) configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it safeguards both positive and negative conductors while providing a dedicated ground path – essential for ungrounded or floating PV arrays common in modern installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eRated at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40kA surge capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and certified to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIEC 61643-31\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this advanced SPD combines the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-energy handling of Type 1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (10\/350µs waveform for direct lightning) with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efast response of Type 2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (8\/20µs waveform for switching surges) – all in a single, compact DIN rail module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ered=replace visual indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ensures you always know your protection status, while \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCE certification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e guarantees compliance with European safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eThreat\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSource\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eConsequence\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDirect Lightning Strike\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStrike to array or mounting structure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInstant destruction, fire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNearby Lightning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStrike to ground near array\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMassive induced voltages\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGrid Switching\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUtility operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransients through inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInverter Switching\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal IGBT switching\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-frequency noise\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eString Faults\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eArcing, ground faults\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvervoltage events\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_2d4e25d3-1f16-4e95-8eb4-b8f9601c3938.jpg?v=1773035208\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_20b3dd01-7c6a-4503-8910-3c13fc2f59aa.jpg?v=1773035207\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_b3bf3f04-c92b-4ef0-9ae9-7135c985ce9f.jpg?v=1773035208\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_ebde0872-e3d9-4e08-a638-d75b8da98f60.jpg?v=1773035208\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_0ac2d4e5-9742-49a5-82d1-ea68ad80c33a.jpg?v=1773035208\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_403b83c3-9409-4d6f-9083-bcbf86f44e55.jpg?v=1773035208\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_89dd1216-5fa9-4966-8395-f7ca62aecf7a.jpg?v=1773035207\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/08_5515ce7c-8689-4648-b058-2cefeca819a5.jpg?v=1773035207\" alt=\"\"\u003e\u003c\/p\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"A type \/ 20KA","offer_id":54063037940084,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true},{"title":"A type \/ 40KA","offer_id":54063037972852,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 20KA","offer_id":54063038005620,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 40KA","offer_id":54063038038388,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_59977e18-3adb-4f50-8558-bce6bad7d21c.png?v=1773035256"},{"product_id":"ac-surge-protective-device-spd-2p-40ka-a-b-type-hkqe-c40-b40-275vac-lightning-surge-arrester-for-home-industrial-ce-certified","title":"AC Surge Protective Device (SPD) 2P 40kA A\/B Type HKQE-C40\/B40 275VAC Lightning Surge Arrester for Home Industrial CE Certified","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e⚡ Ultimate AC Surge Protection for Home \u0026amp; Industry – Type 1+2 Hybrid\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHybrid A\/B Type (Type 1+2):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects against both direct lightning strikes (10\/350µs) and switching surges (8\/20µs) in one device.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh 40kA Surge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Handles major surge events with 20kA nominal discharge current.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2-Pole (2P) Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Safeguards Live (L) and Neutral (N) for complete single-phase protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e275VAC Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ideal for standard 230V residential and light industrial systems (TT\/TN networks).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRed=Replace Visual Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Green means protected, red means replace – at-a-glance status monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCE Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Meets IEC 61643-11 European safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in home distribution boards or industrial panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePower surges are unpredictable and destructive. Whether from a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edirect lightning strike\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a grid switching event, or a motor starting in your facility, transient overvoltages can instantly destroy sensitive electronics or gradually degrade equipment over time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHEVGKEOU AC Surge Protective Device (SPD) Type HKQE-C40\/B40\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehybrid Type 1+2 (A\/B) arrester\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e engineered to provide the highest level of protection for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esingle-phase AC systems up to 275V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It combines the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-energy handling of Type 1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (10\/350µs waveform for direct lightning) with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efast response of Type 2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (8\/20µs waveform for switching surges) – all in a single, compact 2-pole DIN rail module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWith a robust \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40kA maximum discharge capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it's suitable for protecting everything from a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehome entertainment system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindustrial control panels\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The clear \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ered=replace visual indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ensures you always know your protection status at a glance, while \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCE certification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e guarantees compliance with international safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhether you're an electrician installing a main panel protector or a facility manager safeguarding critical equipment, the HKQE-C40\/B40 delivers reliable, maintenance-free protection for years to come.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWhy Choose This SPD\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHome Main Panel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect entire house from surges – one device covers all circuits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHome Office\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect computers, servers, and networking gear\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWorkshop\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafeguard power tools and equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSmall Business\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect POS systems, refrigerators, and lighting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIndustrial Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShield PLCs, VFDs, and motor drives\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTelecom Shelter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect base station power supplies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRetail Store\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafeguard displays, computers, and security systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_375cf459-312f-42b2-8513-c92200367d44.jpg?v=1773035439\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_c27717d0-06de-40e3-a607-0ae5d7afaf42.jpg?v=1773035438\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_624efbb0-9e30-422f-bb52-c554f9c65016.jpg?v=1773035439\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_8b707513-1508-4456-8794-58e33cd4f7d4.jpg?v=1773035439\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_a77811f0-e5d5-4f8f-ab85-8be49bec979f.jpg?v=1773035439\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_5dba5763-a13b-4117-bd63-513fe519efd6.jpg?v=1773035439\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_e0f2b61b-1cb5-4cb7-9330-22636e5f0998.jpg?v=1773035439\" alt=\"\"\u003e\u003c\/p\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"A TYPE 275V \/ 20KA","offer_id":54063048950132,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"A TYPE 275V \/ 40KA","offer_id":54063048982900,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"B TYPE 275V \/ 20KA","offer_id":54063049015668,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"B TYPE 275V \/ 40KA","offer_id":54063049048436,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"A TYPE 385V \/ 20KA","offer_id":54063049081204,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"A TYPE 385V \/ 40KA","offer_id":54063049113972,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"B TYPE 385V \/ 20KA","offer_id":54063049146740,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"B TYPE 385V \/ 40KA","offer_id":54063049179508,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_5473e78c-769c-425f-bb1e-9b52b5044174.png?v=1773035481"},{"product_id":"low-voltage-ac-surge-protective-device-spd-2p-275v-385v-20ka-60ka-discharge-capacity-type-2-surge-arrester-for-house-ac-systems","title":"Low-Voltage AC Surge Protective Device (SPD) 2P | 275V\/385V, 20kA-60kA Discharge Capacity | Type 2 Surge Arrester for House \u0026 AC Systems","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e🏠 Essential Surge Protection for Your Home \u0026amp; AC Units – 20kA to 60kA Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDual Voltage Options:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available in 275V and 385V models to match your local grid (TT\/TN or IT systems).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFlexible Discharge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Choose 20kA, 40kA, or 60kA protection based on your risk level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2-Pole Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects Live (L) and Neutral (N) for complete single-phase coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType 2 Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ideal for main distribution boards, sub-panels, and dedicated AC units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVisual Status Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Green means protected – at-a-glance peace of mind.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in standard household distribution boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eYour home is filled with valuable electronics – from smart TVs and computers to refrigerators, HVAC systems, and entertainment centers. All of them are vulnerable to the destructive power of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003evoltage surges\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Whether from lightning strikes, grid switching, or even your own appliances starting up, these surges can silently damage or instantly destroy your equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLow-Voltage AC Surge Protective Device (SPD) 2P\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is your home's first line of defense. Specifically designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esingle-phase residential and light commercial AC systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this Type 2 surge arrester mounts directly in your distribution board and continuously protects your circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAvailable in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e275V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (for TT\/TN systems) and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e385V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (for IT systems) models, and with discharge capacities from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20kA to 60kA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, you can choose the exact protection level your home needs. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eclear visual status indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e tells you at a glance that your protection is active – green means protected, red means replace.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDon't wait for a surge to prove the value of protection. Safeguard your home and your peace of mind today.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eWhy Your Home Needs This SPD\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eWithout SPD\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWith SPD\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTV, computer, appliances at risk\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEquipment protected from surges\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGradual degradation, shortened life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExtended equipment lifespan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnexpected failures, costly replacements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFewer surprises, lower costs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData loss from power events\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eData preserved\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo indication of risk\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreen light = peace of mind\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect For:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWhy\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMain Home Panel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect everything – one device covers all circuits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDedicated AC Circuit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExpensive HVAC equipment needs protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHome Office\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eComputers, servers, network gear are surge-sensitive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEntertainment Center\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTVs, audio, gaming – don't let a surge ruin movie night\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eKitchen\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefrigerators, ovens, smart appliances are investments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWorkshop\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower tools and equipment need protection too\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_dfb51197-db72-4ee1-837c-9ad18dd17684.jpg?v=1773101247\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_f25efc6f-8330-4a31-a685-af73495c453f.jpg?v=1773101247\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_a3311e4c-f2e0-4e8d-bca4-d187267332d1.jpg?v=1773101247\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_5768030c-f03a-4905-81e8-f52899ed9b2b.jpg?v=1773101247\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_cdbaf692-c93f-4044-83a2-1e27ff9e4d6e.jpg?v=1773101247\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_5e26ba83-ffab-4b63-b811-1375823ef9b2.jpg?v=1773101246\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_c818c2dc-533e-4f21-a5ff-3891a3d93339.jpg?v=1773101247\" alt=\"\"\u003e\n\u003c\/div\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"4P","offer_id":54068553253236,"sku":null,"price":9.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_c980c0c2-d647-4fe0-8a38-8c98d941caca.png?v=1773101313"},{"product_id":"dc-spd-2p-surge-protector-20ka-60ka-275v-385v-low-voltage-arrester-for-house-solar-pv-energy-storage-system-protection","title":"DC SPD 2P Surge Protector 20kA-60kA | 275V\/385V Low-Voltage Arrester for House, Solar PV \u0026 Energy Storage System Protection","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e☀️ Essential DC Surge Protection for Solar \u0026amp; Battery Storage – 20kA to 60kA Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDual Voltage Options:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available in 275V and 385V DC models for various system voltages.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFlexible Discharge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Choose 20kA, 40kA, or 60kA protection based on your risk level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2-Pole Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects both positive (+) and negative (-) DC conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType 2 Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ideal for solar PV arrays, combiner boxes, and battery storage systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVisual Status Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Green means protected – at-a-glance peace of mind.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in standard DC distribution boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSolar PV systems and energy storage installations represent a significant investment – and they're constantly exposed to one of nature's most destructive forces: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elightning and power surges\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Mounted on rooftops or in open fields, these systems are particularly vulnerable to direct and indirect lightning strikes, as well as switching surges from inverters and charge controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e DC SPD 2P Surge Protector\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is specifically engineered to protect \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ephotovoltaic systems, battery storage, and DC distribution equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from damaging transient overvoltages. Available in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e275V and 385V DC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ratings, and with discharge capacities from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20kA to 60kA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, you can choose the exact protection level your system needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-pole (2P) design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e safeguards both positive and negative conductors, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eType 2 protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e handles indirect lightning strikes and switching surges. With \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethermal disconnection protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eclear visual status indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this SPD delivers reliable, maintenance-free protection for years to come.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDon't let a surge destroy your solar investment. Protect your panels, inverters, and batteries with dedicated DC surge protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhy Your Solar System Needs DC Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eWithout DC SPD\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWith DC SPD\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInverter damaged by surges\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInverter survives surges\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePanel degradation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanels protected\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem downtime\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLost energy production\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum ROI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFire risk\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReduced risk\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty may be void\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty maintained\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_1fc9239e-5a48-4394-bcaa-86467adef81a.jpg?v=1773101656\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_f1681e17-f1bb-49d6-b4e7-325f3435515e.jpg?v=1773101656\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_09f21054-f069-4de8-b7da-0239eea59e8c.jpg?v=1773101656\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_caf07b61-8c74-4f81-9024-20741cf4d90e.jpg?v=1773101656\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_a746488e-ae58-49be-8d82-5a2ce4e7ae6a.jpg?v=1773101656\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_b068c2b2-f8b5-4b00-bcde-b9d1864734bb.jpg?v=1773101656\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_252d09a3-2e25-438b-b85e-b9a3492deffd.jpg?v=1773101656\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"A type \/ 275V \/ 20KA","offer_id":54068553908596,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"A type \/ 275V \/ 40KA","offer_id":54068553941364,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"A type \/ 385V \/ 20KA","offer_id":54068553974132,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"A type \/ 385V \/ 40KA","offer_id":54068554006900,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 275V \/ 20KA","offer_id":54068554039668,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 275V \/ 40KA","offer_id":54068554072436,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 385V \/ 20KA","offer_id":54068554105204,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true},{"title":"B type \/ 385V \/ 40KA","offer_id":54068554137972,"sku":null,"price":8.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_236716d5-cb4d-40f4-93be-08044de4828a.png?v=1773101698"},{"product_id":"pv-dc-surge-protective-device-spd-type-2-2-pole-surge-arrester-for-solar-inverters-controllers-lightning-surge-protection-for-photovoltaic-systems","title":"PV DC Surge Protective Device (SPD) Type 2 | 2-Pole Surge Arrester for Solar Inverters \u0026 Controllers | Lightning \u0026 Surge Protection for Photovoltaic Systems","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e☀️ Protect Your Solar Investment – Type 2 DC Surge Protection for PV Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePurpose-Built for Solar:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specifically designed to protect DC-side components like inverters, charge controllers, and combiner boxes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType 2 Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Handles indirect lightning strikes and switching surges (8\/20µs waveform) – the most common threats to PV systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2-Pole (2P) Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Safeguards both positive (+) and negative (-) DC conductors for complete coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Surge Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to 40kA discharge capacity – handles major surge events.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Voltage Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available in 500V, 600V, 800V, and 1000V DC models for residential to utility-scale arrays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVisual Status Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Green means protected – at-a-glance peace of mind.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Easy installation in combiner boxes, inverter enclosures, and DC panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eYour solar PV system represents a significant investment – and it's constantly exposed to one of nature's most destructive forces: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elightning and power surges\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Mounted on rooftops or in open fields, solar arrays are particularly vulnerable to indirect lightning strikes and switching surges from inverters, which can travel through DC lines and destroy expensive components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePV DC Surge Protective Device (SPD) Type 2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is specifically engineered to protect \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esolar inverters, charge controllers, and other DC-side equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from damaging transient overvoltages. With its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eType 2 classification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (8\/20µs waveform), it's designed to handle the most common threats to PV systems: indirect lightning strikes and switching surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-pole (2P) design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e safeguards both positive and negative conductors, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh surge capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (up to 40kA) ensures robust protection for residential, commercial, and utility-scale installations. Available in voltage ratings from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e500V to 1000V DC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, you can choose the exact model that matches your system voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDon't let a surge destroy your inverter or panels. Protect your solar investment with dedicated PV DC surge protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e[Why Solar PV Systems Need DC Surge Protection]\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eThreat\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSource\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eConsequence\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIndirect Lightning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStrike to ground near array\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMassive induced voltages on DC lines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSwitching Surges\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInverter IGBT switching\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-frequency noise, transients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGrid Switching\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUtility operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransients through transformer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eArray Imbalance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFault conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvervoltage events\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNearby Strikes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLightning to nearby structures\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSurges coupled into DC wiring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/01_9bbc4633-03c7-46b3-812f-098e47e65178.jpg?v=1773102046\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/02_b40f8124-0d32-48aa-b98d-6d221dbdda6a.jpg?v=1773102046\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/03_2210e74c-0231-47c4-964f-f517b544cc06.jpg?v=1773102047\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/04_b5c7a1df-1c96-4872-a456-629747a316df.jpg?v=1773102047\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/05_bb0517c0-e21d-449b-bdac-5a3024cf22c8.jpg?v=1773102047\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/06_7b7cf77f-8fcc-49c1-95ab-c43650ac1434.jpg?v=1773102046\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/07_fd108dd0-c69d-4a7e-a9d1-308a0aa47a66.jpg?v=1773102047\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"A TYPE \/ 20KA","offer_id":54065449992564,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true},{"title":"A TYPE \/ 40KA","offer_id":54065450025332,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true},{"title":"B TYPE \/ 20KA","offer_id":54065450058100,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true},{"title":"B TYPE \/ 40KA","offer_id":54065450090868,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_3d3d1e67-8970-431e-9348-9ec094801374.png?v=1773102093"},{"product_id":"adjustable-3-in-1-protection-relay-din-rail-mount-for-over-under-voltage-over-current-40a-63a-230v-ac-voltage-monitoring-relay-for-motors-pumps-hvac-equipment","title":"Adjustable 3-in-1 Protection Relay | DIN Rail Mount for Over\/Under Voltage \u0026 Over Current | 40A\/63A 230V AC | Voltage Monitoring Relay for Motors, Pumps \u0026 HVAC Equipment","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e🔧 Complete 3-in-1 Protection – Adjustable Over\/Under Voltage \u0026amp; Overcurrent\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTriple Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Guards against Over-Voltage, Under-Voltage, and Over-Current in one compact DIN rail device.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFully Adjustable:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Customize voltage thresholds (170-300V) and current limits (1-63A) to match your equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDual Current Options:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available in 40A and 63A models for various load requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDigital Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Real-time monitoring of voltage and current at a glance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAdjustable Delays:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Trip delay and restart delay settings prevent nuisance tripping.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Standard 35mm design for easy installation in industrial and commercial panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eVoltage fluctuations and current overloads are the leading causes of equipment failure in industrial and commercial settings. A sudden spike from the grid, a brownout during peak hours, or a locked rotor in a motor can destroy expensive equipment in seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAdjustable 3-in-1 Protection Relay\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is your complete solution. This advanced device combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eOver-Voltage, Under-Voltage, and Over-Current protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e into a single, easy-to-install DIN rail module – saving panel space and simplifying wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWith \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully adjustable parameters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, you're in complete control. Set exact voltage thresholds and current limits to match your specific equipment. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eclear digital display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e shows real-time voltage and current, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eadjustable time delays\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e prevent nuisance tripping from momentary fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAvailable in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40A and 63A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e models for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V AC single-phase systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this protector is ideal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIndustrial motors and pumps\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHVAC compressors and fans\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRefrigeration equipment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCommercial machinery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAny critical equipment requiring reliable power protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhen a fault occurs, the built-in relay disconnects the load. Once conditions return to normal, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic reset function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e restores power – no manual intervention needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e[Applications]\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWhy You Need It\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIndustrial Motors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrevent burnout from overload or voltage issues\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWater Pumps\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect against dry running, phase issues\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHVAC Compressors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafeguard expensive refrigeration equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRefrigeration Units\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrevent compressor damage from voltage fluctuations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eConveyors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvoid jams and motor damage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMachine Tools\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnsure consistent power quality\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCommercial Equipment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtect refrigerators, freezers, displays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/2_01.jpg?v=1773102918\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/2_02.jpg?v=1773102918\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/2_03.jpg?v=1773102919\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/2_04.jpg?v=1773102918\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/2_05.jpg?v=1773102918\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/2_06.jpg?v=1773102919\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/2_07.jpg?v=1773102918\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/2_08.jpg?v=1773102918\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HEVGKEOU HighQuality Store","offers":[{"title":"63A","offer_id":54068554334580,"sku":null,"price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/files\/1_9bdd91a0-a59a-47c8-b761-45b2235650f2.png?v=1773102969"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0981\/8364\/3508\/collections\/4_2b121acd-ab12-45e9-8c9b-7642e2bcd22e.png?v=1772347537","url":"https:\/\/hevgkeou.com\/collections\/surge-protection-device.oembed","provider":"HEVGKEOU HighQuality Store","version":"1.0","type":"link"}